📞 Call — 404-698-0404
📞 404-698-0404 ✉ Contact Us Serving Georgia, Alabama, North Carolina & Tennessee
Southeast Building Consultants, LLC — Commercial Property Inspections, Property Condition Assessments, Thermal Imaging & Consulting Services

Commercial Roof Infrared Inspections & Roof Moisture Surveys • GA, AL, NC & TN

Roof Moisture Surveys • Low-Slope Roofs

Commercial Roof Infrared Inspections

Infrared roof evaluations for commercial building owners and facility managers — locate thermal anomalies associated with potentially wet roof insulation across Georgia, Alabama, Tennessee & North Carolina.

Advanced Infrared Roof Evaluations for Commercial Building Owners and Facility Managers.

Commercial roofing systems are exposed to constant environmental conditions, including rain, sunlight, wind, and temperature changes.

Over time, roof coverings, flashings, seams, and other components may deteriorate, allowing moisture to enter certain roofing assemblies.

At Southeast Building Consultants, LLC, we offer commercial roof infrared inspections to help identify thermal anomalies that may be associated with potentially wet insulation beneath applicable roof coverings.

Our infrared roof services can support property evaluations, roof maintenance planning, and investigations of suspected moisture intrusion.

Services are available as stand-alone inspections or optional additions to Property Condition Assessments (PCAs), Commercial Building Inspections, and Facility Condition Assessments (FCAs).

Roofing system infrared inspection — example findings from a commercial roof with visible-light references

What Is a Commercial Roof Infrared Inspection?

A commercial roof infrared inspection uses specialized thermographic equipment to evaluate temperature patterns across the surface of a roofing system.

Under suitable conditions, moisture-affected insulation may absorb and release heat differently than surrounding dry materials.

These thermal differences may create patterns that can be identified using infrared imaging equipment.

However, infrared thermography does not directly measure roof moisture content or independently confirm that insulation is wet.

Suspected moisture-related thermal anomalies generally require verification using appropriate testing methods.

Commercial roof infrared inspection services — roof applications, benefits, process, standards and limitations

What Can an Infrared Roof Survey Identify?

Potentially Wet Roof Insulation

Infrared thermography may help identify thermal patterns associated with moisture retained within certain roofing assemblies.

These findings can help direct additional testing toward suspected moisture-affected areas.

Areas Requiring Further Roof Evaluation

Thermal anomalies may indicate locations where roofing materials or underlying components warrant additional investigation.

Suspected Moisture Migration

Depending on the roof assembly and inspection conditions, infrared imaging may help identify patterns associated with moisture distribution beneath the roof covering.

Areas for Maintenance Planning

Documented thermal findings may help property owners and roofing professionals evaluate repair priorities and determine where additional investigation is needed.

Which Commercial Roofs Can Be Evaluated?

Infrared roof moisture surveys may be appropriate for certain low-slope commercial roofing systems.

Examples may include compatible:

  • Built-up roofing assemblies
  • Modified bitumen roofing systems
  • Single-ply membrane roofing systems
  • Other roofing assemblies suitable for infrared moisture evaluation

Not every roof is suitable for an infrared moisture survey.

The roof covering, insulation type, deck construction, surface condition, and moisture retention characteristics can affect whether useful thermal patterns can develop.

Some roofing systems may produce misleading thermal patterns or may not be appropriate for infrared moisture detection.

The suitability of the roof assembly should be evaluated before scheduling a specialized moisture survey.

When Is the Best Time for a Commercial Roof Infrared Inspection?

Specialized infrared roof moisture surveys often require carefully selected environmental conditions.

Depending on the roof assembly and inspection method, favorable conditions may include:

  • Appropriate daytime solar heating
  • Suitable nighttime cooling conditions
  • Limited wind interference
  • Acceptable roof surface conditions
  • Sufficient thermal contrast
  • Safe access to the roofing system

Many roof moisture surveys are performed after sunset when differences in heat retention may become more apparent.

However, nighttime inspection is not appropriate for every application, and the inspection schedule should be based on the roof system and selected methodology.

How Does a Commercial Roof Infrared Inspection Work?

Step 1 — Review the Roofing System

We review available information about the roof construction, age, previous repairs, reported leaks, and inspection objectives.

Step 2 — Determine Survey Suitability

The roof assembly and environmental conditions are evaluated to determine whether infrared thermography is an appropriate method.

Step 3 — Perform the Infrared Roof Survey

Accessible roof areas are evaluated for unusual thermal patterns using appropriate infrared imaging equipment and procedures.

Step 4 — Identify Suspected Moisture-Related Anomalies

Relevant thermal anomalies are documented. Locations requiring additional moisture verification may be identified.

Step 5 — Prepare the Report

The report documents observed thermal patterns, inspection conditions, limitations, and recommendations for additional evaluation or verification.

Benefits of Commercial Roof Infrared Inspections

Support Roof Maintenance Planning

Identify areas that may require additional moisture investigation or repair evaluation.

Help Target Further Testing

Infrared findings can help identify locations for appropriate moisture verification.

Support Roof Replacement Decisions

Information about suspected moisture-affected areas may assist qualified roofing professionals when evaluating repair or replacement options.

Document Roof Conditions

Infrared and visible-light photographs can provide useful records of observed thermal anomalies.

Supplement Commercial Property Assessments

Roof thermography can provide additional information during commercial due diligence and facility planning.

Commercial Roof Infrared Inspection Standards

ASTM C1153 - provides procedures for locating potentially wet insulation in applicable roofing systems using infrared imaging.

ASTM E3216 - provides broader guidance for infrared evaluation of buildings and building systems.

Infraspection Institute - Standard for Infrared Inspection of Insulated Roofs - 2022 Edition - Infraspection Institute Online Store

The selected inspection procedure depends on the roofing system, environmental conditions, and agreed scope of work.

Certified Infrared Thermography Expertise

Southeast Building Consultants, LLC offers infrared services supported by:

  • Level I Infrared Thermography Certification — Infraspection Institute
  • Affiliated Level III Thermography Consulting Support — ITC/FLIR

Personnel qualifications and specialized support are determined by the project requirements.

Important Limitations of Infrared Roof Inspections

Infrared roof thermography cannot independently confirm wet insulation, identify every roof leak, or determine the precise source of moisture intrusion.

Thermal patterns can be influenced by roof construction, insulation thickness, surface materials, previous repairs, trapped heat, weather, and other factors.

Appropriate moisture verification may require additional testing, including invasive methods performed by qualified personnel.

An infrared roof survey does not replace a comprehensive roofing evaluation or establish the remaining service life of a roof.

Frequently Asked Questions

Can infrared imaging find leaks in flat commercial roofs?

Infrared imaging may help identify thermal anomalies associated with potentially wet insulation in suitable roof assemblies. It does not necessarily locate the actual entry point of water.

Does an infrared roof survey require nighttime inspection?

Many specialized roof moisture surveys are performed after sunset, but the appropriate timing depends on the roof construction and inspection methodology.

Can infrared imaging determine whether a roof needs replacement?

No. Thermal findings may support roof evaluation and planning, but replacement decisions require consideration of additional roofing conditions and professional judgment.

Does infrared imaging work on every commercial roof?

No. Some roofing systems and environmental conditions are unsuitable for reliable infrared moisture surveys.

Is roof moisture testing included?

Moisture verification procedures should be specifically identified in the inspection agreement. Infrared imaging alone does not confirm wet insulation.

Evaluate Suspected Roof Moisture Conditions With Infrared Technology.

Southeast Building Consultants, LLC provides commercial roof infrared inspection services to help property owners and facility managers investigate thermal anomalies and plan additional roof evaluations.

Know Your Building. Understand Its Condition. Protect Your Investment.

PCAs • FCAs • Commercial Building Inspections • Infrared Thermography • Serving GA, AL, NC & TN